《中国康复理论与实践》 ›› 2012, Vol. 18 ›› Issue (7): 685-687.

• 论文 • 上一篇    下一篇

折叠盲杖弯曲强度与松晃性能检测

贾亚玲,于娟娟   

  1. 1.中国残疾人辅助器具中心,北京市100050;2.国家康复器械质量监督检验中心,北京市100068。
  • 收稿日期:2012-02-08 修回日期:1900-01-01 出版日期:2012-07-25 发布日期:2012-07-25

Flexural Strength and Loose Performance of Folding Tactile Sticks

JIA Ya-ling, YU Juan-juan.   

  1. China Assistive Devices and Technology Centre for Persons with Disabilities, Beijing 100050, China
  • Received:2012-02-08 Revised:1900-01-01 Published:2012-07-25 Online:2012-07-25

摘要: 目的确定折叠盲杖的两项主要性能弯曲强度和松晃性能的技术指标。方法使用5 支折叠盲杖进行弯曲强度和松晃性能试验,加载后利用运动跟踪系统对标志点的位移进行采集和数据分析。结果和结论弯曲强度测试中,中心部位最大位移量应≤25 mm;松晃性能试验中,松晃量应≤5 mm。

关键词: 折叠盲杖, 质量, 弯曲强度, 松晃性能

Abstract: Objective To determine the technical indicators of flexural strength and loose performance of folding tactile sticks. Methods The bending strength and loose performance of 5 folding tactile sticks were tested, the displacement of the marked point were collected and analyzed with the motion tracking system. Results and Conclusion For the bending strength test, the maximum displacement of the central shall be ≤ 25 mm. For the loose performance test, the loose displacement shall be ≤ 5 mm.

Key words: folding tactile sticks, quality, flexural strength, loose performance